England Pathology and Laboratory Medicine (PaLM) Technical Framework
0.1.0 - ci-build
England Pathology and Laboratory Medicine (PaLM) Technical Framework - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
| Draft as of 2026-11-04 |
{
"resourceType" : "ConceptMap",
"id" : "v2-0085-to-observation-status",
"language" : "en",
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: ConceptMap v2-0085-to-observation-status</b></p><a name=\"v2-0085-to-observation-status\"> </a><a name=\"hcv2-0085-to-observation-status\"> </a><p>Mapping from <a href=\"http://terminology.hl7.org/7.5.0/ValueSet-v2-0085.html\">hl7VS-observationResultStatus</a> to <a href=\"http://hl7.org/fhir/R4/valueset-observation-status.html\">ObservationStatus</a></p><br/><p>Mapping from <a href=\"http://terminology.hl7.org/7.5.0/CodeSystem-v2-0085.html\">observationResultStatusCodesInterpretation</a> to <a href=\"http://hl7.org/fhir/R4/codesystem-observation-status.html\">ObservationStatus</a></p><table class=\"grid\"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>C (Record coming over is a correction and thus replaces a final result)</td><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#concept-map-equivalence-equivalent\" title=\"equivalent\">is equivalent to</a></td><td>corrected</td><td/></tr><tr><td>D (Deletes the OBX record)</td><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#concept-map-equivalence-source-is-narrower-than-target\" title=\"source-is-narrower-than-target\">is narrower than</a></td><td>entered-in-error</td><td/></tr><tr><td>F (Final results)</td><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#concept-map-equivalence-equivalent\" title=\"equivalent\">is equivalent to</a></td><td>final</td><td/></tr><tr><td>I (Specimen in lab; results pending)</td><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#concept-map-equivalence-equivalent\" title=\"equivalent\">is equivalent to</a></td><td>registered</td><td/></tr><tr><td>N (Not asked; used to affirmatively document that the observation identified in the OBX was not sought when the universal service ID in OBR-4 implies that it would be sought.)</td><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#concept-map-equivalence-source-is-narrower-than-target\" title=\"source-is-narrower-than-target\">is narrower than</a></td><td>cancelled</td><td>Not asked - also set Observation.dataAbsentReason = not-asked</td></tr><tr><td>O (Order detail description only (no result))</td><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#concept-map-equivalence-source-is-narrower-than-target\" title=\"source-is-narrower-than-target\">is narrower than</a></td><td>registered</td><td/></tr><tr><td>P (Preliminary results)</td><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#concept-map-equivalence-equivalent\" title=\"equivalent\">is equivalent to</a></td><td>preliminary</td><td/></tr><tr><td>R (Results entered -- not verified)</td><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#concept-map-equivalence-source-is-narrower-than-target\" title=\"source-is-narrower-than-target\">is narrower than</a></td><td>preliminary</td><td/></tr><tr><td>S (Partial results. Deprecated. Retained only for backward compatibility as of V2.6.)</td><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#concept-map-equivalence-source-is-narrower-than-target\" title=\"source-is-narrower-than-target\">is narrower than</a></td><td>preliminary</td><td/></tr><tr><td>U (Results status change to final without retransmitting results already sent as 'preliminary.' E.g., radiology changes status from preliminary to final)</td><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#concept-map-equivalence-source-is-narrower-than-target\" title=\"source-is-narrower-than-target\">is narrower than</a></td><td>final</td><td/></tr><tr><td>W (Post original as wrong, e.g., transmitted for wrong patient)</td><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#concept-map-equivalence-equivalent\" title=\"equivalent\">is equivalent to</a></td><td>entered-in-error</td><td/></tr><tr><td>X (Results cannot be obtained for this observation)</td><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#concept-map-equivalence-source-is-narrower-than-target\" title=\"source-is-narrower-than-target\">is narrower than</a></td><td>cancelled</td><td>Results cannot be obtained - also set Observation.dataAbsentReason</td></tr></table></div>"
},
"url" : "https://examplesihe.org.uk/ConceptMap/v2-0085-to-observation-status",
"version" : "0.1.0",
"name" : "V20085ToObservationStatus",
"title" : "HL7 v2 Observation Result Status to Observation.status",
"status" : "draft",
"experimental" : true,
"date" : "2026-11-04",
"publisher" : "Kevin Mayfield",
"contact" : [
{
"telecom" : [
{
"system" : "url",
"value" : "https://github.com/KevinMayfield/PathologyAndLaboratory"
}
]
}
],
"description" : "HL7 v2 table 0085 Observation Result Status Codes Interpretation (OBX-11) to FHIR `Observation.status`. Indicative, based on the HL7 v2-to-FHIR IG.",
"jurisdiction" : [
{
"coding" : [
{
"system" : "urn:iso:std:iso:3166",
"code" : "GB",
"display" : "United Kingdom of Great Britain and Northern Ireland"
}
]
}
],
"sourceUri" : "http://terminology.hl7.org/ValueSet/v2-0085",
"targetUri" : "http://hl7.org/fhir/ValueSet/observation-status",
"group" : [
{
"source" : "http://terminology.hl7.org/CodeSystem/v2-0085",
"target" : "http://hl7.org/fhir/observation-status",
"element" : [
{
"code" : "C",
"target" : [
{
"code" : "corrected",
"equivalence" : "equivalent"
}
]
},
{
"code" : "D",
"target" : [
{
"code" : "entered-in-error",
"equivalence" : "wider"
}
]
},
{
"code" : "F",
"target" : [
{
"code" : "final",
"equivalence" : "equivalent"
}
]
},
{
"code" : "I",
"target" : [
{
"code" : "registered",
"equivalence" : "equivalent"
}
]
},
{
"code" : "N",
"target" : [
{
"code" : "cancelled",
"equivalence" : "wider",
"comment" : "Not asked - also set Observation.dataAbsentReason = not-asked"
}
]
},
{
"code" : "O",
"target" : [
{
"code" : "registered",
"equivalence" : "wider"
}
]
},
{
"code" : "P",
"target" : [
{
"code" : "preliminary",
"equivalence" : "equivalent"
}
]
},
{
"code" : "R",
"target" : [
{
"code" : "preliminary",
"equivalence" : "wider"
}
]
},
{
"code" : "S",
"target" : [
{
"code" : "preliminary",
"equivalence" : "wider"
}
]
},
{
"code" : "U",
"target" : [
{
"code" : "final",
"equivalence" : "wider"
}
]
},
{
"code" : "W",
"target" : [
{
"code" : "entered-in-error",
"equivalence" : "equivalent"
}
]
},
{
"code" : "X",
"target" : [
{
"code" : "cancelled",
"equivalence" : "wider",
"comment" : "Results cannot be obtained - also set Observation.dataAbsentReason"
}
]
}
]
}
]
}