Enterprise Imaging (Proof of Concept)
0.1.0 - proof-of-concept United Kingdom flag

Enterprise Imaging (Proof of Concept) - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

Placer Order Management [RAD-2]

Placer Order Management [RAD-2] (IHE RAD Scheduled Workflow.b) - the Order Placer (EPR or order communications) places, changes or cancels an imaging order with the Department System Scheduler / Order Filler (RIS).

References

Messages

This guide uses HL7 v2.5.1, as SWF.b requires and as the NW GMSA IG uses.

Message Trigger Use
OMG^O19^OMG_O19 (ORC-1 NW) New order Order Placer places a new order
OMG^O19^OMG_O19 (ORC-1 XO) Change order Order Placer changes an order (v2.5.1 only)
OMG^O19^OMG_O19 (ORC-1 CA) Cancel order Order Placer cancels an order
ORG^O20^ORG_O20 Acknowledgement Order Filler accepts or rejects the order

Parent / child orders (ORC-1 PA / CH) are optional in IHE and not covered here.

sequenceDiagram
    participant OP as Order Placer<br/>EPR / Order Comms
    participant OF as Order Filler<br/>RIS
    OP ->> OF: OMG^O19 / FHIR Message (O19, focus ServiceRequest)
    OF -->> OP: ORG^O20 / FHIR response message

FHIR Message

The FHIR equivalent of OMG^O19 is the Imaging Order (O19) message: a Bundle Message whose MessageHeader has eventCoding v2-0003 O19 and whose focus is the Radiology Service Request. The same message is used for RAD-2 and RAD-3, following the Patient Care Coordination proof of concept, where a referral (REF_I12 or OMG^O19) becomes one O19 FHIR Message whatever the HL7 v2 source. ORG^O20 is a FHIR response message (MessageHeader.response).

Example: Bundle Message - Imaging Order (O19), new order.

FHIR Mapping

Indicative mapping to Radiology Service Request, following the HL7 v2-to-FHIR ORC and OBR maps.

HL7 v2.5.1 FHIR Note
MSH-4 / MSH-6 MessageHeader.sender / destination.receiver (ODS code) Sending / receiving facility
MSH-9 MessageHeader.eventCoding v2-0003 O19 OMG^O19^OMG_O19
PID-3 ServiceRequest.subject (Patient) NHS number and MRN
PV1-19 ServiceRequest.encounter Visit number
ORC-1 ServiceRequest.status / intent NW new, XO change, CA cancel
ORC-2 ServiceRequest.identifier (type PLAC) Placer order number
ORC-12 ServiceRequest.requester Ordering clinician
OBR-4 ServiceRequest.code NICIP code (required), with SNOMED CT map - see Terminology
OBR-13 ServiceRequest.supportingInfo Relevant clinical information
OBR-31 ServiceRequest.reasonCode Reason for study
TQ1-9 ServiceRequest.priority Priority

Example: Radiology Service Request - new order. The accession number is not known to the Order Placer at this point - it is assigned by the RIS (see Filler Order Management [RAD-3] and Procedure Scheduled [RAD-4]).